☰
HomeProductsLONGEVIS Recovery CenterFilmsCasesAcademyAboutFAQContact
← Back to products

ELECTRIC WHOLE-BODY CRYO

ELEC Pro

Flagship Electric Whole-Body Cryochamber

The larger flagship electric format, typically for 2–3 users, with a base internal size of 1 × 1 m.
Fully electric coolingTypically 2–3 usersBase internal size 1 × 1 mFlagship
ELEC Pro Flagship Electric Whole-Body Cryochamber

PRODUCT FILMS

Product Films

Original films; on-screen text and audio have not been translated.

ELEC Pro Electric Chamber Concept Film

A future-facing visual expression of ELEC Pro electric technology and flagship positioning.

PRODUCT OVERVIEW

ELEC Pro is the larger flagship format previously identified as ELEC 1. Typical use is 2–3 people with a base internal size of 1 × 1 m. Size extensions are project configurations. Manufacturer reference parameters are -87°C, 16 kW and approximately 60 minutes of unloaded cooling. Final configuration and performance follow the technical agreement and acceptance. Maximum permitted occupancy and weight still require engineering confirmation.

PRODUCT CAPABILITIES

Capabilities and Project Delivery

ELEC Pro typically accommodates 2–3 users, with a base internal size of 1 × 1 m. Size extensions are project configurations, not additional models.
01

Fully electric cooling

No liquid nitrogen is required.

02

Typical occupancy

Typically 2–3 users; maximum permitted occupancy requires engineering confirmation.

03

Base internal size

1 × 1 m, with installation and size extensions confirmed by project.

04

Performance confirmation

Manufacturer reference: -87°C, 16 kW, approx. 60 min unloaded cooling. Final configuration follows the technical agreement and acceptance. Maximum occupancy, weight, water consumption and throughput require engineering confirmation.

PROJECT DELIVERY

Confirm power, heat rejection, floor loading, access and installation conditions before delivery. Final dimensions and configuration follow the technical agreement.

FAQ

Product Questions

01What is the typical occupancy?+

Typically 2–3 users. This is not a maximum occupancy rating.

02What is the base internal size?+

1 × 1 m. Extensions are project configurations.

03What performance is confirmed?+

Engineering performance remains pending confirmation through a technical agreement and verified tests.

KEY SPECIFICATIONS

Core Specifications

Final configuration is subject to the signed contract, approved design and technical agreement.
Cooling method
Fully electric
Typical occupancy
2–3 people
Base internal size
1 × 1 m
Positioning
Flagship / larger format
Size extensions
By project configuration
Cooling reference
-87°C / 16 kW / approx. 60 min unloaded (manufacturer reference)
Dimension reference
External 1300 × 1300 × 2400 mm / internal 1000 × 1000 × 2000 mm (manufacturer reference)

APPLICATIONS

Where It Fits

01

Premium recovery centers

02

Hotels and resorts

03

Wellness institutions

04

Sports training centers